White Papers

59 Using MLAG in Dell Networking N-Series Switches | version 1.5
A Validation
A.1 Single-Tier Example
Run the show vpc brief command on either MLAG peer to display all information for both peers.
MLAG peer 1 (N3048-1)
MLAG peer 2 (N3048-2)
show vpc brief
VPC domain ID.................................... 1
VPC admin status............................... Enabled
Keep-alive admin status................... Enabled
VPC operational status..................... Enabled
Self role................................................ Primary
Peer role.............................................. Secondary
Peer detection admin status........... Disabled
Operational VPC MAC......................
ECF4.BBF5.2502
Operational VPC system priority…. 32767
peer link details
-----------------
Interface.................................................. Po1
peer link admin status......................... Enabled
peer link STP admin status................. Enabled
Configured VLANs................................. 1,30
Egress tagged VLANs............................ 30
VPC Details
-----------
Number of VPCs configured...................... 2
Number of VPCs operational..................... 2
VPC id# 30
-----------
Interface.................................................... Po30
Configured VLANs.................................. 1,30
VPC interface state................................. Active
Local Members Status
----------------- ------
Gi1/0/47 Up
Peer Members Status
---------------- ------
Gi1/0/11 Up
VPC id# 40
-----------
Interface.............................................. Po40
Configured VLANs............................ 1,30
VPC interface state........................... Active
show vpc brief
VPC domain ID........................................ 1
VPC admin status................................... Enabled
Keep-alive admin status....................... Enabled
VPC operational status......................... Enabled
Self role.................................................. Secondary
Peer role................................................ Primary
Peer detection admin status............... Disabled
Operational VPC MAC..........................
ECF4.BBF5.2502
Operational VPC system priority…….. 32767
peer link details
-----------------
Interface.................................................. Po1
peer link admin status......................... Enabled
peer link STP admin status................. Enabled
Configured VLANs................................. 1,30
Egress tagged VLANs............................ 30
VPC Details
-----------
Number of VPCs configured...................... 2
Number of VPCs operational..................... 2
VPC id# 30
-----------
Interface.................................................... Po30
Configured VLANs.................................. 1,30
VPC interface state................................. Active
Local Members Status
----------------- ------
Gi1/0/11 Up
Peer Members Status
---------------- ------
Gi1/0/47 Up
VPC id# 40
-----------
Interface............................................ Po40
Configured VLANs.......................... 1,30
VPC interface state......................... Active