Users Guide

Images and File Management 533
Figure 14-9. Image Path
3
View information about the current image.
console#show version
Machine Description............ Dell Networking Switch
System Model ID................ N2128PX
Machine Type................... Dell EMC Networking N2128PX-ON
Serial Number.....................
Manufacturer................... 0xbc00
Burned In MAC Address.......... 1418.770C.9DD8
System Object ID............... 1.3.6.1.4.1.674.10895.3077
SOC Version.................... BCM56547_A0
HW Version..................... 2
CPLD Version................... 5
4
Download the image to the switch. After you execute the
copy
command,
you must verify that you want to start the download.
Use either the
active
or
backup
keyword to select the specified image to
replace (which takes effect only after a reboot). In the following example,
the active image is replaced.
console#copy tftp://10.27.65.103/images/dell_0308.stk active
Transfer Mode.................................. TFTP
unit active backup current-active next-active
----- ----------- ----------- --------------- ------------
1 11.3.12.58 10.10.10.53 11.3.12.58 11.3.12.58
2 11.3.12.58 10.20.14.14 11.3.12.58 11.3.12.58