Release Notes
16 Known Issues
Issue ID Functional
Area
Description Workaround/Resolution
MDT-145344
PowerStore
Manager(GUI)
While performing a Refresh Using Related
Volume or Volume Group operation, you
might receive an exception error when
you select Choose One from the drop-
down before you click Refresh. If this
occurs, you must restart PowerStore
Manager.
When refreshing a resource, do not select
the "Choose One" entry in the Refresh from
Volume/Volume Group drop-down.
MDT-163489
PowerStore
Manager(GUI)
Once a node is replaced, the new node
hardware information does not appear in
PowerStore Manager immediately.
After replacing a node, wait up to 30
minutes for the PowerStore Manager screen
to reflect the update.
MDT-130894
PowerStore REST
API
Two invalid resource_types, FEPort and
Initiator, may be returned by the event
and alert APIs.
Events or alerts with resource_type FEPort
or Initiator should ignore the resource_type
values.
External OpenAPI clients must disable
validation for the event and alert APIs with
resource_types of FEPort or Initiator.
MDT-153026 Security
When a drive is inserted into an appliance,
it will take time for D@RE to unlock it.
Most drives take a few minutes. However,
it takes more time for a ColdStream drive
to unlock. The time is proportional to the
size of the Intel Optane SCM drive, for
example, 7 minutes for 375 GB, 15
minutes for 750 GB, and 27 minutes for
1.5TB. If you pull a drive out before it is
unlocked, the drive will appear as
disconnected. However, the drive will not
be automatically removed from the
appliance.
If you intend to use the drive, re-insert the
drive and let the DARE unlock complete. If
you intend to stop using the drive, re-insert
the drive, wait for enough time (time to
unlock plus about 1 minute for other
overhead), and then remove the drive. The
drive will then become disconnected and
automatically removed from the system.
MDT-213516 Security DNS is not supported for LDAP. None
MDT-121966 Storage - File
The File system deleted alert is displayed
as an active alert in PowerStore T even
after the file system has been successfully
deleted.
Review the alert details, to confirm the alert
is for a file system that has been deleted.
Once confirmed, ignore or acknowledge the
pending alert.
MDT-121784 Storage - File
After a NAS server is successfully deleted,
the alerts against the deleted child objects
of the NAS server such as DNS servers, file
systems, NFS exports, or SMB shares, are
not cleared.
Review the alert details, to confirm the alert
is for a child object of a successfully deleted
NAS server. Once confirmed, ignore or
acknowledge the pending alert.