Release Notes

14 Known Issues
Issue ID Functional
Area
Description Workaround/Resolution
MDT-190232 Hardware
The svc_node shutdown command may
reboot the node instead of powering it
off.
Run the svc_node shutdown command
again when the node has finished rebooting.
MDT-137439 Import
If an import from a Unity or VNX2 system
to PowerStore is cancelled by the user or
fails for some reason, it is possible that
subsequent attempts to import the
volume will also fail.
Remove the Unity or VNX2 as a remote
system and then add it again. This action will
clear the issue and allow the import to
proceed.
MDT-174416 Import
Hosts groups are not supported for
agentless import.
None
MDT-167020
Internal
Migration
Migration of a storage resource failed with
the error "Transit object with Handle <id>
: status online on only one node." One of
the nodes of the migration source
appliance was down when the
synchronize phase started. Both nodes
must be online for migration.
Bring the offline node back online and then
try the migration again.
MDT-145764
Internal
Migration
During migration the temporary volumes
that are created during migration are
calculated into the vVol capacity metrics.
The temporary volumes should not be
included in the calculation.
Wait for migration to complete to get the
correct calculation.
MDT-140927
Internal
Migration
After a volume is migrated, there may be
a dip in capacity and performance metrics
reporting for that volume at the end of
the migration operation.
None
MDT-164726
Install or
Upgrade
If the Pre-Upgrade Health Check fails
during an upgrade from PowerStore OS
1.0 to PowerStore OS 1.0.1 or later,
clicking the failed operation link under
Recent activities might result in an error
an error because of a localization issue
with the event message.
None
MDT-220508
Install or
Upgrade
When you are upgrading a PowerStore X
model appliance to PowerStore version
1.0.3.0.5.007, running a Health Check on
the PowerStore software upgrade package
might result in the following error
message:
Internal error has occurred.
Do not perform a Health Check on a
PowerStore X model appliance before the
preupgrade package and node firmware
upgrades are installed on the appliance.
Wait until the preupgrade package and node
firmware upgrades are installed before
performing a Health Check on a PowerStore
X model appliance.