Release Notes

Resolved Issues 11
Issue ID Functional Area Description
MDT-154063 PowerStore CLI The CLI client incorrectly displays embedded arrays of data in tabular output.
MDT-142069
PowerStore
Manager(GUI)
There are situations when the system is Out of Space where the UI is unable to
update its statistics. This situation will be evident by a red banner on the top of
the screen. You may see objects in the UI that are incorrectly displayed as "0
MB/GB/TB" due to the inability for the UI to query for system statistics.
MDT-146618
PowerStore
Manager(GUI)
In the Add Host wizard, the Host Protocol step incorrectly includes a prerequisite
that reads, "...FC-based ethernet switch". It should read, "FC-based switch".
MDT-149011
PowerStore
Manager(GUI)
On the Hardware > Rear View tab for an appliance, once you click Blink LED, the
command is sent immediately, and the LEDs start to blink. It may take a long time
for the Stop Blink LED button to appear in the GUI.
MDT-148153
PowerStore
Manager(GUI)
On the Hardware > Rear View tab for an appliance, port abbreviations such as
FEPort, hFEPort, and vFEPort may not be intuitive. Port abbreviations indicate the
following: FEPort - Physical Frontend Port, hFEPort - Hypervisor Frontend Port,
vFEPort - Virtual Frontend Port
MDT-166702 PowerStore REST API
The discovered_initiator command might fail and return the message "Error:
{'reason': 'java.lang.Integer cannot be cast to java.lang.CharSequence.'}".
MDT-142562 Security
The cancel button of the drive re-purpose confirmation dialog does not close the
dialog when clicked.
MDT-147508 Storage - File
SMB Server cannot join the Active Directory when the SMB server computer name
is more than 15 characters and the first 15 characters of the SMB server computer
name are the same as another SMB server's computer name.
MDT-170429 Storage - File
During manual failover, or failback of the NAS server, the failover, or failback
operation may fail.
MDT-151302 Storage - File
If the network connection is unstable, the DNS may incorrectly be reported as
offline. After restarting the NAS server, the health status of DNS is not cleared if
the DNS is healthy.
MDT-146793 Storage - File
Uploading configuration files to a NAS server, which were edited in WordPad,
does not work as expected.
MDT-143448 Storage - File
"After selecting a file system to delete, the DELETE button is disabled, and no
message or tool-tip is displayed.
MDT-209335 SupportAssist
After enabling SupportAssist, PowerStore Manager displays the connection as
“disabled,” even when the connection was successfully enabled. The status
message will be corrected after 15 minutes.