Reference Guide

CHAPModeEnum
Available CHAP modes that describe or set the iSCSI CHAP mode for the entire cluster.
Disabled
CHAP is not used in the cluster
Single
CHAP is being used to authenticate the initiator
Mutual
CHAP is used to authenticate both the initiator and target
Type : enum (Disabled, Single, Mutual)
ClusterStateEnum
Possible cluster states. * Unconfigured_Faulted - This is single appliance that is not in a cluster and
Hardware is in faulted state. * Unconfigured - This is a single appliance that is not in a cluster. *
Configured - Cluster is configured and operational. * Configuring - Cluster is in the process of initial
setup. * Expanding - Appliance(s) are being added to the cluster. * Removing - Appliance(s) are
being removed from the cluster. * Clustering_Failed - This is a single appliance that failed an
attempt to join a cluster.
Type : enum (Unconfigured_Faulted, Unconfigured, Configuring, Configured, Expanding, Removing,
Clustering_Failed)
CopySessionTypeEnum
Session types.
Type : enum (import_session, migration_session, replication_session)
DataConnectionStateEnum
Possible data connection states of a remote system:
OK
Normal conditions.
Partial_Data_Connection_Loss
Partial data connection loss.
Complete_Data_Connection_Loss
Complete data connection loss.
Status_Not_Available
249
Dell EMC PowerStore REST API Reference Guide