Reference Guide

Option Description
--show_drives
List the drives on the system.
--expansion_resume
Show the output for any attached expansion shelves (DAEs) that are connected.
--cluster
Show information about the cluster.
--services
List all system services across nodes and containers.
--info
Get information such as the node ID, appliance name, service tag, model, IP, and so on.
--energy_star
List all the Energy Star-related information for the appliance.
Example
Use the following command to view local drive Smartdata:
svc_diag list --hardware --sub_options local_drive
Hardware: ========== Local Drive Smartdata ===========
smartctl 7.0 2018-12-30 r4883 [x86_64-linux-4.14.19-coreos-r9999.1551750807-541] (local
build)
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SMART Modular Technologies mSATA XR+ M.2 2280 SafeData MLC
Device Model: SHM2S86Q240GLM22EM 118000653
Serial Number: SPG18040AR2
Firmware Version: FW1146
User Capacity: 240,057,409,536 bytes [240 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: M.2
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Apr 2 19:25:58 2019 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
Example
Use the following command to list all the Energy Star-related information for the appliance:
svc_diag list --energy_star
***** System Energy Star Information *****
Base Enclosure:
Air Inlet Temperature (Celsius) : 22.00 (valid)
Input Power (Watts) : 1360.00 (valid)
Total Appliance InputPower (Watts) : 1360 (valid)
Collect flash and NVMe statistics (svc_drive_stats)
This script collects flash and NVME stats from each drive in an appliance and stores that data in a file. This data sent to Dell
EMC support if SupportAssist has been enabled.
Service Commands
27