Setup Guide

Template Last Updated - 2/7/2007 Initial Configuration of the Switch 15
DELL CONFIDENTIAL – PRELIMINARY 1/16/14 - FOR PROOF ONLY
4
Initial Configuration of the Switch
This section describes how to initially configure the Dell VRTX 1Gb and
10Gb switch modules.
NOTE: Before proceeding further, read the latest documentation and release notes
for this product, which can be downloaded from the Dell Support website at
dell.com/support.
To logon to the switch after it is inserted into the chassis, perform the
following:
1
Turn on the chassis. To display the IP address configured for the out-of-
band interface, go to the CMC GUI, options: I/O Module Overview >
Setup. See the CMC User Guide for further information on how to access
the CMC GUI.
2
Log on to the switch in one of the following ways:
Establish a Telnet session to the out-of-band IP address obtained in
the last step, and log on with the default user/password: root/calvin.
Continue managing the switch through the CLI (see the Dell
PowerEdge VRTX Switch Modules, R1-2401 and R1-2210 CLI
Reference Guides).
Open a GUI session from the CMC GUI, options: I/O Module
Overview > Properties > Launch IOM GUI. In the Login menu,
select either Basic or Advanced mode and use the default
user/password: root/calvin. Continue managing the switch through
the Network Administrator. See the Dell PowerEdge VRTX Switch
Modules, R1-2401 and R1-2210 User Guide.
Connect to the IOM serial interface through the CMC. For that, use
the CMC command: connect switch. See the CMC Command Line
Reference from dell.com/support/manuals.