Reference Guide
Remote Network Monitoring (RMON) Commands 315
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Plasma-ARC
2+3\new_system_mifs_ARC2_latest\RMON.fm
DELL CONFIDENTIAL – PRELIMINARY 4/3/14 - FOR PROOF ONLY
Parameters
•
index
—Specifies the alarm index. (Range: 1–65535)
•
mib-object-id
—Specifies the object identifier of the variable to be
sampled. (Valid OID)
•
interval
—Specifies the interval in seconds during which the data is
sampled and compared with rising and falling thresholds. (Range:
1–4294967295)
•
rising-threshold
—Specifies the rising threshold value. (Range:
0–4294967295)
•
falling-threshold
—Specifies the falling threshold value. (Range:
0–4294967295)
•
rising-event
—Specifies the index of the event triggered when a rising
threshold is crossed. (Range: 0–65535)
•
falling-event
—Specifies the index of the event triggered when a falling
threshold is crossed. (Range: 0–65535)
•
type
{
absolute
|
delta
}—Specifies the method used for sampling the
selected variable and calculating the value to be compared against the
thresholds. The possible values are:
–
absolute
—Specifies that the selected variable value is compared
directly with the thresholds at the end of the sampling interval.
–
delta
—Specifies that the selected variable value of the last sample is
subtracted from the current value, and the difference is compared
with the thresholds.
•
startup
{
rising
|
rising-falling
|
falling
}—Specifies the alarm that may be
sent when this entry becomes valid. The possible values are:
–
rising
—Specifies that if the first sample (after this entry becomes
valid) is greater than or equal to
rising-threshold
, a single rising alarm
is generated.
–
rising-falling
—Specifies that if the first sample (after this entry
becomes valid) is greater than or equal to
rising-threshold
, a single
rising alarm is generated. If the first sample (after this entry becomes
valid) is less than or equal to
falling-threshold
, a single falling alarm is
generated.