Users Guide
Conditions Actions
NOTE: If a Reset Conguration action is performed in
CMC while pinned cache is present, the cache will be
cleared and the data will not be recoverable.
NOTE: Unresolved pinned cache can occur if a virtual
drive goes oine for any reason while there is
uncommitted cache data in memory.
NOTE: When pinned cache is present, the controller
failover feature will not occur. Pinned cache must be
addressed before controller failover is allowed.
• Clear the pinned cache through CMC.
NOTE: Clearing pinned cache means that the pinned data
is lost.
During a Shared PERC rmware ash, virtual drive transitions to
write-through until chassis is recycled.
Allow the chassis reset to complete after the rmware ash.
Virtual drives permanently transition to write-through when the
Hardware failure occurs.
If hardware failure occurs, contact Dell technical support. For more
information, see the Getting help.
In the event of a rmware mismatch, in the dual fault tolerant
Shared PERC 8 congurations, if one controller has write-through
capability and the other does not, virtual drives on the controller
with write-through capability reverts to write-through.
Update the rmware such that both cards are running the latest
supported versions available.
NOTE: Ensure that you download the updated rmware
and driver version available at Dell.com/support/home.
NOTE: Virtual drives congured with forced write-back caching are not transitioned to write-through in the above conditions.
Shared PERC 8 card boots into safe mode
In the event of some failure conditions encountered at boot, Shared PERC 8 boots with restricted capability in safe mode without user
intervention. In such a condition Shared PERC 8 reports all congured disk drives as Foreign to the management application. The Dell
Chassis Management Controller (CMC) displays events generated by the Shared PERC 8 card indicating the reason for booting into safe
mode. The following table details the conditions and the corresponding event notications that are reported to the CMC.
Table 7. Conditions and the corresponding event
notications reported to the CMC
Category Event Reported To the CMC Description of the Failure Corrective Action
Pinned Cache
Controller cache pinned for
missing or offline VDs: %s
The Shared PERC 8 card
preserves dirty cache for a virtual
disk that transitioned to oine or
was deleted due to missing
physical disks.
You can restore the preserved
cache to the virtual disk once the
original drives are reinserted and the
foreign conguration is imported.
SAS Discovery
Controller booted to safe mode
due to critical errors Critical
Error during boot - On-board
expander FW or mfg image is
corrupted - reflash image
This issue occurs if expanders are
not detected.
Reseat the expanders, and connect
the cables.
Critical Error during boot -
NVDATA image is invalid -
reflash NVDATA image
The NVData image is invalid. Contact Dell Technical Support. For
more information, seeGetting help.
Controller is in
safe mode event
RAID Controller in Chassis Slot
X has entered safe mode with
limited functionality due to
Controller booted to safe mode
due to critical errorsRAID
A controller enters safe mode for
the following reasons:
• Incorrect cable congurations
• Controllers with a Fault
Tolerant cable
See the images in the Installation
section to connect the cables
correctly.
58 Troubleshooting