Users Guide
Troubleshooting
To get help with your Dell Shared PowerEdge RAID Controller Shared (PERC) 8 card, you can contact your Dell Technical Service
representative or see Dell.com/contactdell.
Topics:
• General issues
• Physical disk issues
• Virtual disks issues
• Driver issues
• Controller issues
• Hard drive indicator codes
General issues
Shared PERC 8 card not seen in Device Manager
Issue:
The device does not appear in the Device Manager.
Corrective Action: In the Dell Chassis Management Controller (CMC) application, verify if the Shared PERC 8 is correctly mapped to
the server module. For more information on assigning virtual adapters to server slots, see the Dell Chassis
Management Controller for Dell PowerEdge VRTX User’s Guide at Dell.com/poweredgemanuals.
NOTE: Make changes to Virtual Adapter to Server Slot mapping only when the server modules are
turned o.
If the Virtual Adapter to Server Slot mapping is correct and the device still does not appear in the Device
Manager, turn o the system and reseat the Shared PERC 8 card.
Critical errors or disk warning messages seen in the Windows
Event log
Issue:
Error messages such as Critical Event11, PERCSAS2The driver detected a controller
error on \Device\RaidPort...
or,
Warning event: Event 153, Disk
The IO operation at logical block address xxxxxx for Disk x was retried
Referring the PercSAS2 driver is seen in the Windows Event log.
8
Troubleshooting 51