Users Guide

Troubleshooting
To get help with your Dell Shared PowerEdge RAID Controller Shared (PERC) 8 card, you can contact your Dell Technical Service
representative or see Dell.com/contactdell.
Topics:
General issues
Physical disk issues
Virtual disks issues
Driver issues
Controller issues
Hard drive indicator codes
General issues
Shared PERC 8 card not seen in Device Manager
Issue:
The device does not appear in the Device Manager.
Corrective Action: In the Dell Chassis Management Controller (CMC) application, verify if the Shared PERC 8 is correctly mapped to
the server module. For more information on assigning virtual adapters to server slots, see the Dell Chassis
Management Controller for Dell PowerEdge VRTX User’s Guide at Dell.com/poweredgemanuals.
NOTE: Make changes to Virtual Adapter to Server Slot mapping only when the server modules are
turned o.
If the Virtual Adapter to Server Slot mapping is correct and the device still does not appear in the Device
Manager, turn o the system and reseat the Shared PERC 8 card.
Critical errors or disk warning messages seen in the Windows
Event log
Issue:
Error messages such as Critical Event11, PERCSAS2The driver detected a controller
error on \Device\RaidPort...
or,
Warning event: Event 153, Disk
The IO operation at logical block address xxxxxx for Disk x was retried
Referring the PercSAS2 driver is seen in the Windows Event log.
8
Troubleshooting 51