4 Click Chassis Overview → Power → Control → Power On System to turn on the chassis.
5 To enable Fault Tolerance on two Shared PERC 8 External cards, the rmware version must be the same for both cards. Click Chassis
Overview → Storage → Update and upload the necessary rmware image for both Shared PERC 8 External cards.
6 Click Chassis Overview → Storage → Controllers → Troubleshooting → Actions → Enable Fault Tolerance for both controllers.
7 Click Chassis Overview → Power → Control → Power O System to turn o the chassis.
8 Cable enclosure(s) to Shared PERC 8 External cards using required cabling methodology.
NOTE: The cabling topology shown in this section is required to function fault tolerance.
9 Click Chassis Overview → Power → Control → Power On System to turn on the chassis.
NOTE: To transition from one enclosure to two or vice versa, while already in Fault Tolerance, simply turn o the server
modules and enclosure, recable, and then turn on.
Figure 8. Cabling for Shared PERC 8 External card single enclosure Fault Tolerance
Deploying the Shared PERC 8 card