Users Guide

NOTE: Before closing the system, ensure that the release levers have snapped over the edge of the card.
4 Close the system.
Related links
Installing a new Shared PERC 8 Internal card
Replacing a Shared PERC 8 Internal card
Postinstallation tasks for the Shared PERC 8 Internal card
1 Turn on the PowerEdge VRTX system without hard drives and server modules inserted.
NOTE: It may take up to 25 minutes for the PowerEdge VRTX storage subsystem to completely power on.
2 Log in to the CMC GUI.
3 Click OverviewPowerControl, and view the Power State to ensure that it is ON.
4 Click Chassis OverviewStorageControllers to view the rmware version of the replaced Shared PERC 8 Internal card.
The rmware version must be same for both the cards.
NOTE: If the Shared PERC 8 Internal cards have dierent versions of their rmware, download and update the rmware to
the latest version from Dell.com/drivers.
5 If the system has two Shared PERC 8 Internal cards, ensure that the Fault Tolerance Status is Healthy/Normal. This is necessary to
ensure that any new rmware has been initialized and is compatible before you reinsert the shared hard drives and modular servers.
6 Turn o the PowerEdge VRTX system.
7 Insert the shared storage hard drives that you had removed earlier. Insert the shared hard drives in the original slots.
8 Turn on the PowerEdge VRTX system.
9 Check the Virtual Disk Layout and the Virtual Disk Assignments in the CMC GUI. If the virtual disks are not imported, not present, or
the virtual disk assignments are not present or are incorrect, contact Dell Technical Support.
10 Turn o the PowerEdge VRTX system.
11 Insert the server modules that you had removed earlier. Insert the server modules in the original slots.
12 Turn on the PowerEdge VRTX system.
13 Turn on the server modules.
Related links
Installing a new Shared PERC 8 Internal card
Replacing a Shared PERC 8 Internal card
Installing a new Shared PERC 8 External card
To install a new Shared PERC 8 External card in the PowerEdge system, perform the following steps:
1 Install the Shared PERC 8 External card. SeeInstalling the Shared PERC 8 External card.
2 Postinstallation tasks for the Shared PERC External card. SeePostinstallation tasks for the Shared PERC 8 External card.
Replacing a Shared PERC 8 External card
When replacing an existing Shared PERC 8 External card in the PowerEdge VRTX system, perform the following steps to ensure proper
functionality of the shared storage after the replacement process is complete.
1 Prerequisites for removing the Shared PERC External card. SeePrerequisites for removing the Shared PERC 8 External card.
2 Remove the Shared PERC External card. SeeRemoving the Shared PERC 8 External card.
3 Install the Shared PERC External card. SeeInstalling the Shared PERC 8 External card.
4 Postinstallation tasks for the Shared PERC External card. SeePostinstallation tasks for the Shared PERC 8 External card.
24