Reference Guide

466 Statistics/RMON
Startup Alarm
— Select the trigger that activates the alarm. The
possible options are:
Rising Alarm
— A rising counter value triggers the alarm
Falling Alarm
— A falling counter value triggers the alarm.
Rising and Falling
— Both rising and falling counter values
trigger the alarm.
Interval (1–2147483647)
— Enter the alarm interval time in seconds.
This is the interval in seconds over which the data is sampled and
compared with the rising and falling thresholds.
Owner
— Enter the name of the user or network management system
that receives the alarm.
Defining Device Alarms Using the CLI Commands
The following table contains the CLI commands for defining device alarms.
Table 21-10. Device Alarm CLI Commands
CLI Command Description
rmon alarm index
MIB_Object_ID interval
rising-threshold falling-
threshold rising-event
falling-event [type
{absolute|delta}][startup
{rising|rising-
falling|falling}][owner
name]
no rmon alarm index
Configures RMON alarm conditions.
Use the no form of this command to
remove an alarm.
show rmon alarm-table Displays summary of the alarm table.
show rmon alarm number Displays the RMON alarm
configuration.