Reference Guide

LLDP 397
Hold Multiplier (2-10) —
Enter the hold time to be sent in the
LLDP update packets, as a multiple of the timer value.
Reinitializing Delay (1-10)
— Enter the minimum time, in seconds,
that an LLDP port waits before reinitializing LLDP transmission.
Transmit Delay (1-8192)
— Enter the amount of time that passes
between successive LLDP frame transmissions, due to changes in the
LLDP local systems MIB.
To use the default values for any field, select
Use Default
.
Configuring LLDP Using CLI Commands
The following commands are used to set the fields in the LLDP Properties
page.
Table 17-1. LLDP Properties CLI Commands
CLI Command Description
lldp run
no lldp run
Enables enable LLDP.
Use the no form of this command to
disable LLDP.
lldp timer seconds
no lldp timer
Specifies how often the software sends
LLDP updates.
Use the no form of this command to
restore the default configuration.
lldp hold-multiplier number
no lldp hold-multiplier
Specifies the time that the receiving
device should hold a Link Layer Discovery
Protocol (LLDP) packet before discarding
it.
Use the no form of this command to
restore the default configuration.
lldp reinit seconds
no lldp reinit
Specifies the minimum time an LLDP
port will wait before reinitializing.
Use the no form of this command to revert
to the default setting.