Reference Guide

386 Multicast Support
Operational Query Max Response Interval
—Displays the delay used
to calculate the Maximum Response Code inserted into the General
Queries.
Last Member Query Counter (1-7)
—Enter the Last Member Query
Count to be used if the device cannot derive the value from the
messages sent by the elected querier.
Operational Last Member Query Counter
—Displays the
operational value of the Last Member Query Counter.
Last Member Query Interval (100-25500)
—Enter the Maximum
Response Delay to be used if the device cannot read Max Response
Time value from Group-Specific queries sent by the elected querier.
Operational Last Member Query Interval
—The Last Member
Query Interval sent by the elected querier.
Immediate Leave
—When enabled, reduces the time it takes to block
unnecessary MLD traffic sent to a device port.
MLD Querier Status
—Enable or disable MLD querier.
MLD Querier Election
—Enable or disable MLD election.
MLD Querier Version
—Select the MLD querier version.
4
Click
Apply
. The Running Configuration file is updated.