Reference Guide

314 Remote Network Monitoring (RMON) Commands
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Plasma-ARC
2+3\new_system_mifs_ARC3_latest\RMON.fm
DELL CONFIDENTIAL – PRELIMINARY 5/21/14 - FOR PROOF ONLY
falling
—Specifies that if the first sample (after this entry becomes
valid) is less than or equal to
falling-threshold
, a single falling alarm is
generated.
owner
name
—Specifies the name of the person who configured this alarm.
(Valid string)
Default Configuration
The default method type is absolute.
The default startup direction is rising-falling.
If the owner name is not specified, it defaults to an empty string.
Command Mode
Global Configuration mode
Example
The following example configures an alarm with index 1000, MIB object ID
D-Link, sampling interval 360000 seconds (100 hours), rising threshold value
1000000, falling threshold value 1000000, rising threshold event index 10,
falling threshold event index 10, absolute method type and rising-falling
alarm.
console(config)#
rmon alarm
1000 1.3.6.1.2.1.2.2.1.10.1 360000
1000000 1000000 10 20
show rmon alarm-table
Use the show rmon alarm-table Privileged EXEC mode command to display a
summary of the alarms table.
Syntax
show rmon alarm-table
Command Mode
Privileged EXEC mode