Reference Guide

Remote Network Monitoring (RMON) Commands 313
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Plasma-ARC
2+3\new_system_mifs_ARC3_latest\RMON.fm
DELL CONFIDENTIAL – PRELIMINARY 5/21/14 - FOR PROOF ONLY
Parameters
index
—Specifies the alarm index. (Range: 1–65535)
mib-object-id
—Specifies the object identifier of the variable to be
sampled. (Valid OID)
interval
—Specifies the interval in seconds during which the data is
sampled and compared with rising and falling thresholds. (Range:
1–4294967295)
rising-threshold
—Specifies the rising threshold value. (Range:
0–4294967295)
falling-threshold
—Specifies the falling threshold value. (Range:
0–4294967295)
rising-event
—Specifies the index of the event triggered when a rising
threshold is crossed. (Range: 0–65535)
falling-event
—Specifies the index of the event triggered when a falling
threshold is crossed. (Range: 0–65535)
type
{
absolute
|
delta
}—Specifies the method used for sampling the
selected variable and calculating the value to be compared against the
thresholds. The possible values are:
absolute
—Specifies that the selected variable value is compared
directly with the thresholds at the end of the sampling interval.
delta
—Specifies that the selected variable value of the last sample is
subtracted from the current value, and the difference is compared
with the thresholds.
startup
{
rising
|
rising-falling
|
falling
}—Specifies the alarm that may be
sent when this entry becomes valid. The possible values are:
rising
—Specifies that if the first sample (after this entry becomes
valid) is greater than or equal to
rising-threshold
, a single rising alarm
is generated.
rising-falling
—Specifies that if the first sample (after this entry
becomes valid) is greater than or equal to
rising-threshold
, a single
rising alarm is generated. If the first sample (after this entry becomes
valid) is less than or equal to
falling-threshold
, a single falling alarm is
generated.