Users Guide

Virtual Disks
A logical grouping of physical disks attached to a PERC S130 allows creating multiple virtual disks of the same RAID levels,
without exceeding a maximum of ten virtual disks.
The PERC S130 controller allows:
Creating virtual disks of different RAID levels on a S130 controller.
NOTE: Ensure that you do not mix RAID levels on the same physical disks.
Building different virtual disks with different characteristics for different applications.
The PERC S130 controller does not allow:
Creating a virtual disk from a mix of different type physical disks. For example, a RAID 10 virtual disk cannot be created from
two SATA HDD physical disks and a SATA SSD physical disk. All of the physical disks must be of the same drive type (HDD
or SSD).
Selecting a physical disk as a dedicated hot spare if the physical disk is a different type from the physical disk of the virtual
disks.
A virtual disk refers to data storage, which a controller creates using one or more physical disks.
NOTE: A virtual disk can be created from several physical disks, the operating system considers it a single disk.
The capacity of a virtual disk can be expanded online for any RAID level without rebooting the operating system.
Topics:
Virtual disk features
Virtual disk features
TRIM for SATA SSDs
The TRIM command allows an operating system to delete a block of data that is no longer considered in use from the SATA
SSDs. TRIM resolves the Write Amplification issue for supported operating systems. When an operating system deletes a file,
the file is marked for deletion in the file system, but the contents on the disk are not actually erased. As a result, the SSDs do
not know that the Logical Block Addressing (LBA) file previously occupied can be erased. With the introduction of TRIM, when a
file is deleted, the operating system sends a TRIM command along with the LBAs that do not contain valid data.
NOTE: The TRIM feature is supported only on pass-through SSDs.
NOTE: The TRIM feature is not supported on NVMe PCIe SSDs.
To perform TRIM on the pass-through SSDs
1. Create a volume on a pass-through SSD drive.
2. In the Windows operating system, navigate to the Defragmentation and Optimize Drive tool.
3. Select the volume created on the pass-through SSD and click Optimize.
TRIM is applied.
Disk initialization
For physical disks, initialization writes metadata to the physical disk so that the controller can use the physical disk.
3
Virtual Disks 13