Users Guide
Convert to RAID capable
Prerequisites
To convert a non–RAID disk to RAID capable disk from the HII Configuration Utility, perform the following steps:
Steps
1. Enter the Dell PERC 11 Configuration Utility. See Navigate to Dell PERC 11 configuration utility.
2. Click Main Menu > Physical Disk Management.
The list of physical disks appears.
3. Select the physical disk.
4. From the Operations drop-down menu, select Convert to RAID capable.
5. Click Go.
A screen appears asking if you are sure you want to perform the operation.
6. Select the Confirm option.
7. Click Yes.
The operation is successful.
Convert to Non–RAID disk
Prerequisites
To convert a physical disk to non–RAID disk from the HII Configuration Utility, perform the following steps:
Steps
1. Enter the Dell PERC 11 Configuration Utility. See Navigate to Dell PERC 11 configuration utility.
2. Click Main Menu > Physical Disk Management.
The list of physical disks appears.
3. Select the physical disk.
4. From the Operations drop-down menu, select Convert to Non–Raid disk.
5. Click Go.
A screen appears asking if you are sure you want to perform the operation.
6. Select the Confirm option.
7. Click Yes.
The operation is successful.
Hardware components
View battery properties
Steps
1. Enter the Dell PERC 11 Configuration Utility. See Navigate to Dell PERC 11 configuration utility.
2. Click Main Menu > Hardware Components > Battery Management.
The battery and capacity information are displayed.
3. You can view the following properties of the battery:
Table 16. Battery properties
Field Description
Type Displays the type of battery available.
Status Displays the current status of the battery.
58 Manage PERC 11 controllers using HII configuration utility