Users Guide
Steps
1. Enter the Dell PERC 11 Configuration Utility. See Navigate to Dell PERC 11 configuration utility.
2. Click Main Menu > Virtual Disk Management.
The list of virtual disks is displayed.
3. Select the virtual disk.
NOTE: Consistency check cannot be run on RAID 0 virtual disks.
4. From the Operations drop-down menu, select Check Consistency.
5. Click Go.
A screen is displayed asking if you are sure you want to perform the operation.
6. Select the Confirm option.
7. Click Yes.
The consistency check operation is completed successfully.
Physical disk management
View physical disk properties
Steps
1. Enter the Dell PERC 11 Configuration Utility. See Navigate to Dell PERC 11 configuration utility.
2. Click Main Menu > Physical Disk Management.
All the physical disks associated with the RAID controller are displayed.
3. To view the properties, click the physical disk.
Table 14. Physical disk properties
Option Description
Operation The list of operations you can perform on the selected physical disk. The
options are:
● Blink
● Unblink
● Assign global hotspare
● Cryptographic erase
● Convert to non–RAID disk
Device ID Unique identifier of the physical disk.
Backplane ID Backplane ID in which the physical disk is located in for PERC H755 adapter,
PERC H755 front SAS, and PERC H755N front NVMe.
Slot number The drive bay in which the physical disk is located for the corresponding
backplane or enclosure to which the controller is connected.
Status Status of the physical disk.
Size Size of the physical disk.
Type Type of the physical disk.
Model Model of the physical disk.
Serial number Serial of the physical disk.
4. To view additional properties of the physical disk, click Advanced....
Manage PERC 11 controllers using HII configuration utility
55