Users Guide

Table Of Contents
A screen appears asking if you are sure you want to perform the operation.
6. Select the Confirm option.
7. Click Yes.
The operation is successful.
Convert to NonRAID disk
Prerequisites
To convert a physical disk to nonRAID disk from the HII Configuration Utility, perform the following steps:
Steps
1. Enter the Dell PERC 11 Configuration Utility. See Navigate to Dell PERC 11 configuration utility.
2. Click Main Menu > Physical Disk Management.
The list of physical disks appears.
3. Select the physical disk.
4. From the Operations drop-down menu, select Convert to NonRaid disk.
5. Click Go.
A screen appears asking if you are sure you want to perform the operation.
6. Select the Confirm option.
7. Click Yes.
The operation is successful.
Hardware components
View battery properties
Steps
1. Enter the Dell PERC 11 Configuration Utility. See Navigate to Dell PERC 11 configuration utility.
2. Click Main Menu > Hardware Components > Battery Management.
The battery and capacity information are displayed.
3. You can view the following properties of the battery:
Table 16. Battery properties
Field Description
Type Displays the type of battery available.
Status Displays the current status of the battery.
Temperature Displays the current temperature of the battery and also indicates whether the
temperature is normal or high.
Charge Displays the available charge of the battery in percentage.
4. Displays click Advanced....
The additional advanced properties of the physical battery are displayed.
5. You can view the following advanced properties of the battery:
Table 17. Advanced battery properties
Field Description
Status Displays whether the current status of the battery is learning, degraded, or failed.
Voltage Displays whether the voltage status of the battery is normal or high.
62 Manage PERC 11 controllers using HII configuration utility