Users Guide
Table Of Contents
- Dell EMC PowerEdge RAID Controller 10 User’s Guide PERC H345, H740P, H745, H745P MX, and H840
- Contents
- Overview
- Getting Started
- Features
- Controller features
- Virtual disk features
- Hard drive features
- Fault tolerance
- Operating system device enumeration
- Controller mode
- Non-RAID disk
- Deploying the PERC card
- Removing the PERC H345 adapter
- Installing the PERC H345 adapter
- Removing the PERC H345 front card
- Installing the PERC H345 front card
- Removing the PERC H740P adapter
- Installing the PERC H740P adapter
- Removing the PERC H740P mini monolithic
- Installing the PERC H740P mini monolithic
- Removing the PERC H745 adapter
- Installing the PERC H745 adapter
- Removing the PERC H745 front card
- Installing the PERC H745 front card
- Removing the PERC H745P MX adapter card
- Installing the PERC H745P MX adapter card
- Removing the PERC H840 card
- Installing the PERC H840 card
- Part replacement of a PERC card in eHBA mode
- Part replacement of a PERC card in RAID mode with another in eHBA mode
- Driver installation
- Creating the device driver media
- Windows driver installation
- Installing the driver during a Windows Server 2012 R2 and newer installation
- Installing the driver after Windows Server 2012 R2 and newer installation
- Updating PERC 10 driver for existing Windows Server 2012 R2 and newer
- Linux driver installation
- Firmware
- HII configuration utility
- Entering the HII configuration utility
- Exiting the HII configuration utility
- Navigating to Dell PERC 10 configuration utility
- HII Configuration utility dashboard view options
- Configuration management
- Controller management
- Virtual disk management
- Physical disk management
- Hardware components
- Security key management in the HII configuration utility
- Security key and RAID management
- Security key implementation
- Local Key Management
- Creating security key
- Changing Security Settings
- Disabling security key
- Create secured virtual disk
- Secure non-RAID disks
- Secure preexisting virtual disk
- Importing secure virtual disk
- Import secured non-RAID disk
- Dell EMC OpenManage Secure Enterprise Key Manager
- Troubleshooting
- Single virtual disk performance or latency in hypervisor configurations
- Adapter at baseport not responding error message
- BIOS disabled error message
- Configured disks removed or not accessible error message
- Dirty cache data error message
- Discovery error message
- Drive Configuration Changes Error Message
- Windows operating system installation errors
- Firmware fault state error message
- Extra enclosure error message
- Foreign configuration found error message
- Foreign configuration not found in HII error message
- Degraded state of virtual disks
- Memory errors
- Preserved Cache State
- Security key errors
- General issues
- Physical disk issues
- Physical disk in failed state
- Unable to rebuild a fault tolerant virtual disk
- Fatal error or data corruption reported
- Physical disk displayed as blocked
- Multiple disks are inaccessible
- Rebuilding data for a failed physical disk
- Virtual disk fails during rebuild using a global hot spare
- Dedicated hot spare disk fails during rebuild
- Redundant virtual disk fails during reconstruction
- Virtual disk fails rebuild using a dedicated hot spare
- Physical disk takes a long time to rebuild
- SMART errors
- Replace member errors
- Linux operating system errors
- Drive indicator codes
- HII error messages
- Appendix RAID description
- Getting help
- Documentation resources
Setting up redundant path support on the PERC H840 adapter
The PERC H840 card can detect and use redundant paths to disks contained in enclosures. With redundant paths to the same
device, if one path fails, another path can be used to communicate between the controller and the device.
To connect single enclosure, cable the ports so that the enclosure is connected to both the ports on the controller card. See
Figure 6. PERC H840 Card ports - Four enclosures with multipath configuration in PERC H840 enclosure support.
Profile Management
PERC 10 introduces the concept of profiles. A profile is user selectable. It defines controller queue depth and the maximum
number of physical and virtual disks. There are two profiles: PD64 and PD240. The H740 supports only the PD64 profile. The
H745P MX supports only the PD240 profile. The H840 supports both PD64 and PD240. PD240 is the default profile on H840.
For more information see Changing profile using HII Configuration Utility.
NOTE: When an H740 or H840 controller is upgraded to firmware version 50.3.0-1022 from an older firmware version, the
profile on the controller is set to PD64 by default.
Table 2. Supported Profiles on PERC 10
Feature PD64 PD240
Profile ID 10 12
Maximum physical disk supported 64 240
Maximum virtual disk supported 64 240
Controller queue depth 4096 3072
Maximum enclosure supported
● One enclosure using multipath
configuration
● Two enclosure using single path
configuration
● Four enclosure using multipath
configuration
● Eight enclosure using single path
configuration
NOTE: In the MX chassis, H745P MX supports seven enclosures using a multipath configuration.
NOTE: PD64 is supported on both internal and external controllers, whereas PD240 is supported only on the H840 and
H745P MX.
Secure firmware update
This feature provides a cryptographic method of updating the firmware using an RSA encryption-decryption algorithm.
Only Dell-certified firmware is supported on your PERC controller.
Snapdump
The Snapdump feature provides the Dell support team with the debug information which can help to find the cause of firmware
failure. In the instance of firmware failures, the firmware collects the logs and information at the time of failure, which are
stored in a compressed file called a snapdump.
Snapdumps are also generated manually to provide additional debug information. When a snapdump is generated, it is stored in
the controller's cache memory. This means in the event of a power loss the controller will offload the snapdump as part of its
cache preservation mechanism. Snapdumps are preserved by default through four reboots before its deleted.
To generate a snapdump, change the snapdump, delete a snapdump, and to download a stored snapdump settings, see Dell
EMC PowerEdge RAID Controller CLI Reference Guide at www.dell.com/storagecontrollermanuals.
Virtual disk features
This section lists the following virtual disk features supported on PERC 10 cards in detail:
22
Features