Users Guide

ます。お使いのシステムの SAS ケーブルが間違って接続されている可能性がありま
す。
対応処置:
ケーブル接続を確認し、問題を修正した後、システムを再起動します。ケーブルに問
題がない場合、任意のキー、または <C> を押して続行します。
ダーティーキャッシュデータエラーメッセージ
エラーメッセー
The following virtual disks are missing: (x). If you proceed
(or load the configuration utility), these virtual disks will
be removed from your configuration. If you wish to use them at
a later time, they will have to be imported. If you believe
these virtual disks should be present, please power off your
system and check your cables to ensure all disks are present.
Press any key to continue, or 'C' to load the configuration
utility. The cache contains dirty data, but some virtual disks
are missing or will go offline, so the cached data cannot be
written to disk. If this is an unexpected error, then please
power off your system and check your cables to ensure all disks
are present. If you continue, the data in cache will be
permanently discarded. Press 'X' to acknowledge and permanently
destroy the cached data.
考えられる原
コントローラは、仮想ディスクがオフラインになるか、物理ディスクの欠落によって
削除された場合、仮想ディスクのダーティーキャッシュを保持します。このメッセー
ジは、構成済みのディスクの一部が取り外されたことを示します。ディスクが取り外
されていない場合は、アクセスできなくなっています。お使いのシステムの
SAS ケー
ブルが誤って接続されている可能性があります。
対応処置: ケーブル接続を確認し、問題を修正した後、システムを再起動します。<Ctrl> <R> ユー
ティリティを使用して仮想ディスクをインポートするか、保持キャッシュを破棄しま
す。保持キャッシュの管理手順については、トピック「保持キャッシュの管理」を参
照してください。
BIOS 無効エラーメッセージ
エラーメッセー
ジ:
BIOS Disabled. No Logical Drives Handled by BIOS.
考えられる原因
この警告メッセージは、設定ユーティリティで ROM オプションを無効にした後に表示
されます。ROM オプションが無効になっていると、BIOS Int 13h で起動できず、仮
想ディスクから起動する機能を提供できません。Int 13h BIOS に送信される多数の
コマンドをサポートする割り込み信号で、BIOS に送信された後は物理ディスクに渡さ
れます。コマンドには、読み取り、書き込み、フォーマットなど、物理ディスクで実
行できる操作が含まれます。
対応処置
ROM オプションを有効化します。
ドライブ設定変更エラーメッセージ
エラーメッセー
ジ:
Entering the configuration utility in this state will result in
drive configuration changes. Press 'Y' to continue loading the
75