Reference Guide
BIOS.MemSettings.FirmwareVersion23 (Read or Write)
Description
The firmware revision of this NVDIMM.
Legal Values None
Default Value Not Applicable
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependency Not applicable
BIOS.MemSettings.FRMPercent (Read or Write)
Description
Select to define the percent of total memory size that must be used by the fault resilient mode, when
selected in the Memory Operating mode. When Fault Resilient Mode is not selected, this option is grayed
out and not used by Fault Resilient Mode.
This option is grayed out(read only) when "Fault Resilient Mode" is not selected in "Memory Operating
Mode". This option is only available on Intel platforms.
Legal Values
● 25
● 12.5
Default Value Not Applicable
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependency Not applicable
BIOS.MemSettings.IntelPersistentMemories (Read or Write)
Description
View and configure installed Intel Persistent Memories.
Legal Values None
Default Value Not Applicable
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependency Not applicable
BIOS.MemSettings.IntelPersistMemOperationTarget (Read or
Write)
Description
NVDIMM region creation target in per Platform or per Socket.
Legal Values
● PmPlatform
● PmSocket
Default Value Not Applicable
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependency Not applicable
BIOS Attributes 153