Users Guide
65 Dell EMC PowerEdge MX SmartFabric Configuration Guide with Cisco ACI
4. Verify that the interface includes all required VLANs and EPGs. Repeat the steps for the remaining
interfaces as needed.
5. Repeat the steps in this section for the remaining leaf switch.
5.4.3 Verify ACI learning endpoints
To verify that the ACI is learning endpoints, perform the following steps:
1. In the APIC GUI, go to Tenants > Tenant name > Application Profiles > Application Profile name >
Application EPGs > and select an Application EPG.
2. Click the Operational tab in the navigation window as shown in Figure 56.
Cisco ACI endpoints in appEPG1
3. Review the listing of the learned endpoints for the selected EPG along with the VLAN, IP address,
and interface.
4. Repeat the steps in this section for the remaining Application EPGs.
5.4.4 Verify ACI VMM domain integration
To verify ACI vCenter domain integration:
1. In the APIC GUI, Go to Virtual Networking > VMM Domains > VMware > VDS-ACI, click the
Operational option on the top right corner. The vCenter-server and its details such as number of
hypervisors and virtual machines, displays.