63 Dell EMC PowerEdge MX SmartFabric Configuration Guide with Cisco ACI
3. Verify that all of the leaf switch interfaces in the vPC, for example, eth1/51-52, are listed beneath the
port channel and are also Up.
4. With the port channel/vPC interface policy group selected in the left pane, click VLANs at the top of
the right pane as shown in Figure 53.
Cisco ACI vPC port channel VLANs and EPGs
5. Verify that the port channel includes all required VLANs, and that the EPGs are mapped to the
correct VLANs.
6. Repeat the steps in this section for the remaining leaf switch.
5.4.2 Verify physical interface configuration
The physical, host-connected, interfaces in the validated environment are those connected directly to the
PowerEdge R730xd servers as shown in Figure 4.
Verify the physical interfaces from the Cisco ACI fabric to the servers are up and properly configured to allow
designated VLANs and EPGs. To verify the configuration, perform the following steps:
1. In the APIC GUI, go to Fabric > Inventory > Pod 1 > Leaf name > Interfaces > Physical
Interfaces as shown in Figure 54.