57 Dell EMC PowerEdge MX SmartFabric Configuration Guide with Cisco ACI
--------------------------------------------------------------------------
CBJWLN2 MX7116n FEM 1 CF54XM2 A1 1/1/1 71
5.2.3 show unit-provision
The show unit-provision command is only available on the MX9116n FSE. It displays the unit ID,
name, and the state of each MX7116n FEM attached to the MX9116n FSE.
MX9116n-1# show unit-provision
Node ID | Unit ID | Provision Name | Discovered Name | State |
---------+---------+---------------------------------+-------|
1 | 71 | CBJWLN2 | CBJWLN2 | up |
(output truncated)
5.2.4 show vlt domain-id
The show vlt domain-id command validates the VLT configuration status. The role of one switch in the
VLT pair is primary (not shown), and its peer switch is assigned the secondary role. The VLT domain ID of
255 is automatically configured in SmartFabric mode. The VLTi link Status and VLT Peer Status must both be
up. SmartFabric automatically configures the VLTi as port channel 1000.
MX9116n-1# show vlt 255
Domain ID : 255
Unit ID : 1
Role : secondary
Version : 1.0
Local System MAC address : 20:04:0f:00:b8:1e
VLT MAC address : 20:04:0f:00:b8:1e
IP address : fda5:74c8:b79e:1::1
Delay-Restore timer : 90 seconds
Peer-Routing : Disabled
Peer-Routing-Timeout timer : 0 seconds
VLTi Link Status
port-channel1000 : up
VLT Peer Unit ID System MAC Address Status IP Address Version
--------------------------------------------------------------------------------
2 20:04:0f:00:9d:1e up fda5:74c8:b79e:1::2 1.0
5.2.5 show vlt domain-id vlt-port-detail
The show vlt domain-id vlt-port-detail command shows the VLT port channel status for both
VLT peers. The VLT in this example is connected to the Cisco ACI vPC. It is automatically configured in port
channel 1, and it consists of two ports on each switch.
MX9116n-1# show vlt 255 vlt-port-detail
vlt-port-channel ID : 1
VLT Unit ID Port-Channel Status Configured ports Active ports
-------------------------------------------------------------------------------
* 1 port-channel1 up 2 2
2 port-channel1 up 2 2