Users Guide

56 Dell EMC PowerEdge MX SmartFabric Configuration Guide with Cisco ACI
Figure 51 shows ports 1/1/1 and 1/1/3 are up. Ports 1/1/1 and 1/1/3 are connected to the compute sleds in the
local chassis. The figure also shows the uplinks to the Cisco ACI leafs, using port channel 1, are up. It also
shows the VLTi ports, using port channel 1000, are up.
IOM port information
5.2 Validation using the MX9116n FSE CLI
The CLI commands shown in this section are available to help validate the configuration. The commands and
output shown below are from the MX9116n FSE in the first chassis. The CLI output from the MX9116n FSE in
the second chassis, not shown, is similar.
Note: The MX9116n FSE CLI is accessible using SSH. The default username and password are both admin.
5.2.1 show switch-operating-mode
Use the show switch-operating-mode command to display the current operating mode.
MX9116n-1# show switch-operating-mode
Switch-Operating-Mode : Smart Fabric Mode
5.2.2 show discovered-expanders
The show discovered-expanders command is only available on the MX9116n FSE and displays the
MX7116n FEMs service tag attached to the MX9116n FSEs and the associated port-group and virtual slot.
MX9116n-1# show discovered-expanders
Service Model Type Chassis Chassis-slot Port-group Virtual
tag service-tag Slot-Id