Users Guide

24 Dell EMC PowerEdge MX SmartFabric Configuration Guide with Cisco ACI
Access Port Selector for vPC interfaces
g. Click Submit.
4.2.8 Create a VPC Domain Policy
To create VPC Domain Policy, perform the following steps:
1. Go to Fabric > Access Policies > Policies > Switch > VPC Domain.
2. Right-click on VPC Domain and select Create VPC Domain Policy.
3. In the Name field, enter vPCDom1.
4. Click Submit.
Create vPC Domain Policy
4.2.9 Create a VPC Explicit Protection Group
1. Click Fabric > Access Policies > Policies > Switch and select Virtual Port Channel default.
2. Leave Pairing Type set to Explicit (default).
3. Next to Explicit VPC Protection Groups, click the Add(+) icon.
4. In the Name field, enter vPCExpProGrp1.
5. In the ID field, enter 101.
6. From the VPC Domain Policy drop-down, select vPCDom1 (created above in step 4.2.8).
7. For Switch 1, select the first leaf switch, 101/Leaf1.