Users Guide
20 Dell EMC PowerEdge MX SmartFabric Configuration Guide with Cisco ACI
4.2.4 Create a Port Channel Policy
To create Port Channel Policy:
1. Go to Fabric > Access Policies > Policies > Interface > Port Channel.
2. Right-click on Port Channel and select Create Port Channel Policy.
3. In the Name field, enter LACPPol1.
4. From the Mode drop-down, select LACP Active.
Note: When LACP is enabled on the leaf switch, it must also be enabled on the connected devices
5. Keep default settings that are shown in the Control field.
6. Click Submit.
Create Port Channel Policy
4.2.5 Create a vPC Interface Policy Group
When interfaces are configured in vPC, interface policy group needs to be created. vPC policy group contains
the port channel behavior definition and the identifier.
1. Go to Fabric > Access Policies > Interfaces > Leaf Interfaces > Policy Groups > VPC
Interface.
2. Right-click on VPC Interface and select Create VPC Interface Policy Group.
3. In the Name field, enter vPCPolGrp1.
4. From the Attached Entity Profile drop-down, select AEP1 (created above in step 4.2.3).
5. From the Port Channel Policy drop-down, select LACPPol1 (created above in step 4.2.4).
6. Click Submit.