Reference Guide
67 Dell EMC PowerEdge MX SmartFabric Deployment Guide
9.5.2 Validation using the MX9116n CLI
The CLI commands shown in this section are available to help validate the configuration. The commands and
output shown below are from the MX9116n in the first chassis. The CLI output from the MX9116n in the
second chassis, not shown, is similar.
Note: The MX9116n CLI is accessible using SSH. The default username and password are both admin.
9.5.2.1 show switch-operating-mode
Use the show switch-operating-mode command to display the current operating mode.
MX9116n-1# show switch-operating-mode
Switch-Operating-Mode : Smart Fabric Mode
9.5.2.2 show discovered-expanders
The show discovered-expanders command is only available on the MX9116n FSE and displays the
MX7116n FEMs service tag attached to the MX9116n FSEs and the associated port-group and virtual slot.
MX9116n-1# show discovered-expanders
Service Model Type Chassis Chassis-slot Port-group Virtual
tag service-tag Slot-Id
--------------------------------------------------------------------------
CBJWLN2 MX7116n FEM 1 CF54XM2 A1 1/1/1 71
9.5.2.3 show unit-provision
The show unit-provision command is only available on the MX9116n FSE. It displays the unit ID, name,
and the state of each MX7116n FEM attached to the MX9116n FSE.
MX9116n-1# show unit-provision
Node ID | Unit ID | Provision Name | Discovered Name | State |
---------+---------+---------------------------------+-------|
1 | 71 | CBJWLN2 | CBJWLN2 | up |
(output truncated)