Reference Guide

46 Dell EMC PowerEdge MX SmartFabric Deployment Guide
Per-vlan consistency status : success
Type-2 inconsistency reason : Consistency Check Not Performed
vPC role : secondary, operational primary
Number of vPCs configured : 1
Peer Gateway : Disabled
Dual-active excluded VLANs : -
Graceful Consistency Check : Enabled
Auto-recovery status : Disabled
Delay-restore status : Timer is off.(timeout = 30s)
Delay-restore SVI status : Timer is off.(timeout = 10s)
vPC Peer-link status
---------------------------------------------------------------------
id Port Status Active vlans
-- ---- ------ --------------------------------------------------
1 Po255 up 1,10
vPC status
----------------------------------------------------------------------
id Port Status Consistency Reason Active vlans
-- ---- ------ ----------- ------ ------------
255 Po1 up success success 1,10
8.3.2 show vpc consistency-parameters
The show vpc consistency-parameters command displays the configured values on all interfaces in
the vPC. The displayed configurations are only those configurations that limit the vPC peer link and vPC from
coming up.
NX3232C-Leaf1# show vpc consistency-parameters vpc 255
Legend:
Type 1 : vPC will be suspended in case of mismatch
Name Type Local Value Peer Value
------------- ---- ---------------------- -----------------------
STP Port Type 1 Normal Port Normal Port
STP Port Guard 1 Default Default
STP MST Simulate PVST 1 Default Default
lag-id 1 [(1000, [(1000,
20-4-f-0-cd-1e, 1, 0, 20-4-f-0-cd-1e, 1, 0,
0), (7f9b, 0), (7f9b,
0-23-4-ee-be-ff, 80ff, 0-23-4-ee-be-ff, 80ff,
0, 0)] 0, 0)]
mode 1 active active
delayed-lacp 1 disabled disabled
Speed 1 100 Gb/s 100 Gb/s
Duplex 1 full full
Port Mode 1 trunk trunk
Native Vlan 1 1 1
MTU 1 1500 1500