Users Guide

show uplink brief
Displays the uplink port information.
Syntax
show uplink {brief|detail}
Parameters
brief Enter the keyword brief to display a brief summary of the uplink port information.
detail Enter the keyword detail to display uplink port information with description.
Command Modes
EXEC Privilege
Supported Modes All Modes
Command History
Version Description
9.4(0.0) Supported on the FN I/O Aggregator.
8.3.17.0 Supported on the M I/O Aggregator.
Example (brief)
Dell#show uplink brief
---------------- show uplink brief ---------------------
Interface OK Status Protocol Description
TenGigabitEthernet 0/41 NO up down
TenGigabitEthernet 0/43 NO up down
TenGigabitEthernet 0/44 NO up down
TenGigabitEthernet 0/45 NO up down
TenGigabitEthernet 0/46 NO up down
TenGigabitEthernet 0/47 NO up down
TenGigabitEthernet 0/48 NO up down
TenGigabitEthernet 0/49 NO up down
TenGigabitEthernet 0/50 NO up down
TenGigabitEthernet 0/51 NO up down
TenGigabitEthernet 0/52 NO up down
TenGigabitEthernet 0/53 NO up down
TenGigabitEthernet 0/54 NO up down
TenGigabitEthernet 0/55 NO up down
TenGigabitEthernet 0/56 NO up down
TenGigabitEthernet 1/41 NO up down
TenGigabitEthernet 1/42 NO up down
TenGigabitEthernet 1/43 NO up down
--More--
4 www.force10networks.com (10.11.84.18) 000.000 ms 000.000 ms 000.000 ms
Dell#
Example (detail)
Dell#show uplink detail
---------------- show uplink detail ---------------------
TenGigabitEthernet 0/41 is up, line protocol is down
Hardware is DellForce10Eth, address is 00:1e:c9:f1:00:99
Current address is 00:1e:c9:f1:00:99
Port is not prsent
Pluggable media not present
Interface index is 44634881
Internet address is not set
Mode of IP Address Assignment : NONE
DHCP Client-ID :tenG170001ec9f10099
MTU 12000 bytes, IP MTU 11982 bytes
LineSpeed auto
Flowcontrol rx on tx off
ARP type: ARPA, ARP Timeout 04:00:00
Last clearing of "show interface" counters 2d19h53m
Queueing strategy: fifo
Input Statistics:
74