Users Guide

Supported Modes All Modes
Command History
Version Description
8.3.17.0 Supported on the M I/O Aggregator.
Usage Information If there are no ber ports in the unit, just the header under show inventory media displays. If there are ber ports but no optics inserted, the output displays
"Media not present or accessible".
Example
Dell#show inventory
System Type : PE-FN-410S-IOA
System Mode : 1.0
Software Version : 1-0(0-1859)
Unit Type Serial Number Part Number Rev Piece Part ID Rev Svc Tag Exprs Svc Code
---------------------------------------------------------------------------------------------------------------------
* 0 PowerEdge-FN-410S-IOA TW000000000020 07NVPVX01 X01 TW-07NVPV-00000-000-0020 X01 N/A N/A
* - Management Unit
Software Protocol Configured
--------------------------------------------------------------
DCBX
FIP Snooping
IGMP
iSCSI
LLDP
SNMP
Dell#
Example (media)
Dell#show inventory media ?
<0-5> Slot number
| Pipe through a command
Dell#show inventory media
Slot Port Type Media Serial Number F10Qualified
------------------------------------------------------------------------------
0 9 SFP+ 10GBASE-CU1M APF11380028XGQ Yes
0 10 SFP+ 10GBASE-CU2M APF12090032HDL Yes
0 11 SFP+ 10GBASE-CU2M APF12090032HFB Yes
0 12 SFP+ 10GBASE-CU0.5M APF12490013FP2 Yes
Dell#
Example (optional-
module)
Dell#show inventory optional-module
Unit Slot Expected Inserted Next Boot Status/Power(On/Off)
------------------------------------------------------------------------
1 0 SFP+ SFP+ AUTO Good/On
1 1 QSFP+ QSFP+ AUTO Good/On
* - Mismatch
Dell#
Related Commands
show cong (from INTERFACE VLAN mode) — displays information on a specic physical interface or virtual interface.
show memory
Display current memory usage on the M I/O Aggregator.
Syntax
show memory [stack-unit 0–5]
Control and Monitoring
61