Users Guide

show fcoe-map
Display the Fibre Channel and FCoE conguration parameters in FCoE maps.
Syntax
show fcoe-map
Parameters None
Command Modes
EXEC
EXEC Privilege
Supported Modes All Modes
Command History
Version Description
9.3(0.0) Introduced on the M I/O Aggregator.
Usage Information
Use the show fcoe-map command to display the FC and FCoE parameters used to congure server-
facing Ethernet (FCoE) and fabric-facing FC ports in all FCoE maps on an M I/O Aggregator Switch.
In each FCoE map, the values for the fabric ID and FC-MAP that identify the SAN fabric to which FC
storage trac is sent, and the FCoE VLAN to be used must be unique.
An FCoE map is used to identify the SAN fabric to which FCoE storage trac is sent. It also virtualizes M
I/O Aggregator Switch with the FC Flex IO module FC ports so that they appear to downstream server CNA
ports as FCoE Forwarder (FCF) ports on an FCoE network.
Example
Dell(conf)#do show fcoe-map
Fabric Name SAN_FABRIC
Fabric Type npiv
Fabric Id 1002
Vlan Id 1002
Vlan priority 3
FC-MAP 0efc00
FKA-ADV-Period 8
Fcf Priority 128
Config-State ACTIVE
Oper-State UP
=======================================================
Members
Fc 0/41 Fc 0/42 Fc 0/43 Fc 0/44 Fc 0/49 Fc 0/50 Fc 0/51 Fc 0/52
Te 0/4 Te 0/9 Te 0/16
=======================================================
=======================================================
Dell(conf)#
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between
servers and a SAN fabric.
152