Users Guide

Example
ENode[0]:
ENode MAC : 00:10:18:f1:94:21
ENode Intf : Te 0/12
FCF MAC : 5c:f9:dd:ef:10:c8
Fabric Intf : Fc 0/5
FCoE Vlan : 1003
Fabric Map : fid_1003
ENode WWPN : 20:01:00:10:18:f1:94:20
ENode WWNN : 20:00:00:10:18:f1:94:21
FCoE MAC : 0e:fc:03:01:02:01
FC-ID : 01:02:01
LoginMethod : FLOGI
Secs : 5593
Status : LOGGED_IN
ENode[1]:
ENode MAC : 00:10:18:f1:94:22
ENode Intf : Te 0/13
FCF MAC : 5c:f9:dd:ef:10:c9
Fabric Intf : Fc 0/0
FCoE Vlan : 1003
Fabric Map : fid_1003
ENode WWPN : 10:00:00:00:c9:d9:9c:cb
ENode WWNN : 10:00:00:00:c9:d9:9c:cd
FCoE MAC : 0e:fc:03:01:02:02
FC-ID : 01:02:01
LoginMethod : FDISC
Secs : 5593
Status : LOGGED_IN
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers and a SAN fabric.
show running-cong fcoe-map
Displays the current fcoe-map congurations.
M I/O Aggregator with the FC Flex IO module
Syntax
show running-config fcoe-map
Command Modes EXEC Privilege
Supported Modes All Modes
Command History
Version Description
9.6(0.0) Supported on the FN2210S Aggregator.
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex
IO module.
Example
Dell(conf)#do show running-config fcoe-map
!
fcoe-map map
fc-map 0efc00
fabric-id 100 vlan 100
142
FC Flex IO Modules