To remove an FCoE map from an FC interface, enter the no fabric map-name command in Interface
conguration mode.
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between
servers and a SAN fabric.
show fcoe-map— displays the Fibre Channel and FCoE conguration parameters in FCoE maps.
fabric-id vlan
In an FCoE map, congure the association between the dedicated VLAN used to carry FCoE trac between servers and a SAN, and
the fabric where the desired storage arrays are installed.
M I/O Aggregator with the FC Flex IO module
Syntax
fabric-id fabric-num vlan vlan-id
Parameters
fabric-id fabric-num Enter a fabric ID number that is the same as the ID number of the dedicated VLAN
used to carry FCoE storage trac to the fabric specied in the FCoE map. You can
enter a fabric ID in the range 1–4094.
vlanvlan-id Enter the ID number of the dedicated VLAN used to carry FCoE storage trac
between servers and a SAN fabric and specied with the vlan command in the
FCoE map.
Defaults None
Command Modes FCOE MAP
Supported Modes Programmable-Mux (PMUX)
Command History
Version Description
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex
IO module.
Usage Information
In the fabric-id vlan command, the fabric and VLAN ID numbers must be the same.
In each FCoE map, the fabric ID, FC-MAP value, and FCoE VLAN parameters must be unique.
To remove a fabric-VLAN association from an FCoE map, enter the no fabric-id vlan command.
You must rst create a VLAN and then specify the congured VLAN ID in the fabric-id vlan
command. Otherwise, the following error message is displayed.
FTOS(conf-fcoe-f)#fabric-id 10 vlan 10 % Error: Vlan 10 does not exist
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between
servers and a SAN fabric.
show fcoe-map— displays the Fibre Channel and FCoE conguration parameters in FCoE maps.
132