Users Guide

Version Description
9.3(0.0) Introduced on the M I/O Aggregator.
Usage Information
An FCoE map is a template used to map FCoE and FC parameters in a converged fabric. An FCoE map is
used to virtualize upstream FC ports on an FN2210S Aggregator with the PMUX module NPIV proxy
gateway so that they appear to downstream server CNA ports as FCoE forwarder (FCF) ports on an FCoE
network. When applied to FC and Ethernet ports on an NPIV proxy gateway, an FCoE map allows the switch
to operate as an FCoE-FC bridge between an FC SAN and an FCoE network by providing FCoE-enabled
servers and switches with the necessary parameters to log in to a SAN fabric.
On an FN2210S Aggregator a with the PMUX module NPIV proxy gateway, you cannot apply an FCoE map
applied on fabric-facing FC ports and server-facing 10–Gigabit Ethernet ports.
An FCoE map consists of the following parameters: the dedicated FCoE VLAN used for storage trac, the
destination SAN fabric (FC-MAP value), FCF priority used by a server, and the FIP keepalive (FKA)
advertisement timeout.
In each FCoE map, the fabric ID, FC-MAP value, and FCoE VLAN parameters must be unique. Use one
FCoE map to access one SAN fabric. You cannot use the same FCoE map to access dierent fabrics.
To remove an FCoE map from an Ethernet interface, enter the no fcoe-map map-name command in
Interface conguration mode.
fcoe priority-bits
Congure the FCoE priority advertised for the FCoE protocol in application priority TLVs.
Syntax
fcoe priority-bits priority-bitmap
To remove the congured FCoE priority, use the no fcoe priority-bits command.
Parameters
priority-bitmap Enter the priority-bitmap range. The range is from 1 to FF.
Defaults 0x8
Command Modes PROTOCOL LLDP
Supported Modes Programmable-Mux (PMUX)
Command History
Version Description
9.4(0.0) Supported on the FN I/O Aggregator.
9.3(0.0) Introduced on the FC Flex IO module installed in the M I/O Aggregator.
Usage Information This command is available at the global level only.
Data Center Bridging (DCB)
103