User's Manual

3. Create the dedicated VLAN to be used for FCoE traffic.
Dell(conf)#interface vlan 1002
4. Configure an FCoE map to be applied to the downstream (server-facing) Ethernet and
upstream (core-facing) FC ports.
Dell(config)# fcoe-map SAN_FABRIC_A
Dell(config-fcoe-name)# fabric-id 1002 vlan 1002
Dell(config-fcoe-name)# description "SAN_FABRIC_A"
Dell(config-fcoe-name)# fc-map 0efc00
Dell(config-fcoe-name)# keepalive
Dell(config-fcoe-name)# fcf-priority 128
Dell(config-fcoe-name)# fka-adv-period 8
5. Enable an upstream FC port.
Dell(config)# interface fibrechannel 0/0
Dell(config-if-fc-0)# no shutdown
Dell (config-if-fc-0)# fabric SAN_FABRIC_A
6. Enable a downstream Ethernet port.
Dell(config)#interface tengigabitEthernet 0/0
Dell(conf-if-te-0)# no shutdown
Dell (conif-if-te-0)# fcoe-map SAN_FABRIC_A
Displaying NPIV Proxy Gateway Information
To display NPG operation information, use the following show commands.
Command
Description
Show interfaces status
Displays the operational status of Ethernet
and Fibre Channel interfaces.
show fcoe-map [brief | map-
name]
Displays the FC and FCoE configuration
parameters in FCoE maps.
show qos dcb-map map-name
Displays the configuration parameters in a
specified DCB map.
show npiv devices [brief]
Displays information on FCoE and FC devices
currently logged in to the NPG.
show fc switch
Displays the FC mode of operation and
worldwide node (WWN) name.