User's Manual
Task
Command
Command Mode
Configure a fabric-facing FC
port.
interface
fibrechannel
slot/port
CONFIGURATION
Apply the FCoE and FC fabric
configurations in an FCoE map
to the port.
Repeat this step to apply an
FCoE map to more than one
FC port.
fabric map-name
INTERFACE
FIBRE_CHANNEL
Enable the port for FC
transmission.
no shutdown
INTERFACE
FIBRE_CHANNEL
You can apply a DCB or FCoE map to a range of Ethernet or Fibre Channel interfaces by using
the interface range command; for example:
Dell(config)# interface range tengigabitEthernet 1/12 - 23 ,
tengigabitEthernet 2/24 – 35
Dell(config)# interface range fibrechannel 0/0 - 3 ,
fibrechannel 0/8 – 11
Enter the keywords interface range then an interface type and port range. The port
range must contain spaces before and after the dash. Separate each interface type and port
range with a space, comma, and space.
Sample Configuration
1. Configure a DCB map with PFC and ETS settings.
Dell(config)# dcb-map SAN_DCB_MAP
Dell(config-dcbx-name)# priority-group 0 bandwidth 60 pfc
off
Dell(config-dcbx-name)# priority-group 1 bandwidth 20 pfc
on
Dell(config-dcbx-name)# priority-group 2 bandwidth 20 pfc
on
Dell(config-dcbx-name)# priority-pgid 0 0 0 1 2 0 0 0
2. Apply the DCB map on a downstream (server-facing) Ethernet port.
Dell(config)# interface tengigabitethernet 1/0
Dell(config-if-te-0/0)#dcb-map SAN_DCB_MAP