User's Manual

FCoE VLAN
server CNA to a fabric and configured on both the server-facing IOA
and MXL switch with the FC Flex IO module port and server CNA
Fabric Map
Enode WWPN
Enode WWNN
FCoE MAC
MAP value in the FCoE map and the FC-ID provided by the fabric
after a successful FLOGI. In the FPMA, the most significant bytes are
FC-ID
LoginMethod
Secs
State
Configuring an NPIV Proxy Gateway
Prerequisite: Before you configure an NPIV proxy gateway on an IOA or MXL switch with the FC
Flex IO module, ensure the following:
DCB is enabled by default.
DCB (PFC and ETS) parameters are configured for converged traffic.
To configure NPG operation on an IOA and MXL switch with the FC Flex IO module, follow these
steps:
1. Enable Fibre Channel capability on the switch.
2. Create a DCB map.
3. Apply a DCB map on server-facing Ethernet ports.
4. Create an FCoE VLAN.
5. Create an FCoE map.
6. Apply an FCoE map on server-facing Ethernet ports.
7. Apply an FCoE Map on fabric-facing FC ports.