User's Manual
ENode WWPN : 10:00:00:00:c9:d9:9c:cb
ENode WWNN : 10:00:00:00:c9:d9:9c:cd
FCoE MAC : 0e:fc:03:01:02:02
FC-ID : 01:02:01
LoginMethod : FDISC
Secs : 5593
Status : LOGGED_IN
See the following tables for field descriptions.
Related Command
• dcb-map
• fcoe-map
The following table describes the show npiv devices brief output.
Field
Description
ENode-Intf
IOA and MXL switch with the FC Flex IO module Ethernet interface
(slot/port) to which a server CNA is connected.
ENode-WWPN
Worldwide port name (WWPN) of a server CNA port.
FCoE-Vlan
VLAN ID of the dedicated VLAN used to transmit FCoE traffic to and
from the fabric.
Fabric_Intf
Fabric-facing Fibre Channel port (slot/port) on which FC traffic is
transmitted to the specified fabric.
Fabric-Map
Name of the FCoE map containing the FCoE/FC configuration
parameters for the server CNA-fabric connection.
LoginMethod
Method used by the server CNA to log in to the fabric; for example:
FLOGI - ENode logged in using a fabric login (FLOGI).
FDISC - ENode logged in using a fabric discovery (FDISC).
Status
Operational status of the link between a server CNA port and a SAN
fabric:
Logged In - Server has logged in to the fabric and is able to transmit
FCoE traffic.
The following table describes the show npiv devices output.
Field
Description
ENode [number]
A server CNA that has successfully logged in to a fabric over an IOA
and MXL switch with the FC Flex IO module Ethernet port in ENode
mode.
Enode MAC
MAC address of a server CNA port.
Enode Intf
Port number of a server-facing Ethernet port operating in ENode
mode.
FCF MAC
Fibre Channel forwarder MAC: MAC address of IOA and MXL switch
with the FC Flex IO module FCF interface.
Fabric Intf
Fabric-facing Fibre Channel port (slot/port) on which FCoE traffic is
transmitted to the specified fabric.