1. Configure stack groups on all stack units.
Dell#
Dell#configure
Dell(conf)#stack-unit 0 stack-group 0
Dell(conf)#00:37:46: %STKUNIT0-M:CP %IFMGR-6-
STACK_PORTS_ADDED: Ports Fo 0/33 have been configured as
stacking ports. Please save and reset stack-unit 0 for
config to take effect
Dell(conf)#stack-unit 0 stack-group 1
Dell(conf)#00:37:57: %STKUNIT0-M:CP %IFMGR-6-
STACK_PORTS_ADDED: Ports Fo 0/37 have been configured as
stacking ports. Please save and reset stack-unit 0 for
config to take effect
Dell(conf)#end
Dell#00:38:16: %STKUNIT0-M:CP %SYS-5-CONFIG_I: Configured
from console
2. Reload the stack units.
Dell#reload
Proceed with reload [confirm yes/no]: yes
3. Show the units stacking status.
Dell#show system brief
Stack MAC : 00:01:e8:e1:e1:c3
Reload-Type : normal-reload [Next boot :
normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp
Version Ports
---------------------------------------------------------
0 Management online I/O-Aggregator I/O-
Aggregator <<release version>> 56
1 Standby online I/O-Aggregator I/O-
Aggregator <<release version>> 56
2 Member not present
3 Member not present
4 Member not present
5 Member not present
Dell#