User's Manual
2. Configure the VLT domain.
Dell#configure
Dell(conf)#vlt domain 1
Dell(conf-vlt-domain)# peer-link port-channel 127
-> VLT peer destination
Dell(conf-vlt-domain)# back-up destination 169.254.31.23
Dell(conf-vlt-domain)#system-mac mac-address
00:01:09:06:06:06
-> unit-id 0 – VLT Primary, unit-id 1 – VLT Secondary
Dell(conf-vlt-domain)# unit-id 0
Dell(conf-vlt-domain)#end
3. Configure the VLT port channel. In the following example, the local and remote VLT
port-channels are the same but you can also use different VLT port-channels.
Dell#configure
Dell(conf)#int port-channel 128
Dell(conf-if-po-128)# portmode hybrid
Dell(conf-if-po-128)# switchport
Dell(conf-if-po-128)# vlt-peer-lag port-channel 128
Dell(conf-if-po-128)# link-bundle-monitor enable
Dell(conf-if-po-128)# no shutdown
Dell(conf-if-po-128)# end
4. Show the VLT peer status.
Dell#show vlt brief
VLT Domain Brief
------------------
Domain ID: 1
Role: Primary
Role Priority: 32768
ICL Link Status: Up
HeartBeat Status: Up
VLT Peer Status: Up
Local Unit Id: 0
Version: 6(2)
Local System MAC address: 00:01:e8:e1:e1:c3
Remote System MAC address: f8:b1:56:0e:b1:7f
Configured System MAC address: 00:01:09:06:06:06
Remote system version: 6(2)
Delay-Restore timer: 90 seconds
Peer-Routing : Disabled
Peer-Routing-Timeout timer: 0 seconds
Multicast peer-routing timeout: 150 seconds