User's Manual
Uplink Failure Detection (UFD)
UFD provides detection of the upstream connectivity loss and, if used with network interface
controller (NIC) teaming, automatic recovery from a failed link.
1. Create the UFD group and associate the downstream and upstream ports.
Dell#configure
Dell(conf)#uplink-state-group 1
Dell(conf-uplink-state-group-1)#
Dell(conf-uplink-state-group-1)#upstream port-channel 128
Dell(conf-uplink-state-group-1)#downstream
tengigabitethernet 0/1-32
2. Show the running configurations in the UFD-group 1.
Dell(conf-uplink-state-group-1)#show config
!
uplink-state-group 1
downstream TenGigabitEthernet 0/1-32
upstream Port-channel 128
Dell(conf-uplink-state-group-1)#
3. Show the UFD status.
Dell#show uplink-state-group detail
(Up): Interface up (Dwn): Interface down (Dis):
Interface disabled
Uplink State Group : 1 Status: Enabled, Up
Upstream Interfaces : Po 128(Up)
Downstream Interfaces : Te 0/1(Dwn) Te 0/2(Dwn) Te 0/3(Dwn)
Te 0/4(Up) Te 0/5(Up)
Te 0/6(Dwn) Te 0/7(Up) Te 0/8(Dwn)
Te 0/9(Dwn) Te 0/10(Dwn)
Te 0/11(Dwn) Te 0/12(Up) Te
0/13(Up) Te 0/14(Dwn) Te 0/15(Up)
Te 0/16(Dwn) Te 0/17(Dwn) Te
0/18(Dwn) Te 0/19(Dwn) Te 0/20(Dwn)
Te 0/21(Dwn) Te 0/22(Dwn) Te
0/23(Dwn) Te 0/24(Dwn) Te 0/25(Dwn)
Te 0/26(Dwn) Te 0/27(Dwn) Te
0/28(Dwn) Te 0/29(Dwn) Te 0/30(Dwn)
Te 0/31(Dwn) Te 0/32(Dwn)
Dell#