Reference Guide

Control and Monitoring | 55
Example
Figure 5-11. show environment thermal-sensor Command Example
show inventory
Displays the switch type, components (including media), FTOS version including hardware
identification numbers and configured protocols.
Syntax
show inventory {[media slot] | [optional-module]}
Parameters
Defaults
none
Command Modes
EXEC
Command
History
Usage
If there are no fibre ports in the unit, only the header under show inventory media is displayed. If
there are fibre ports but no optics inserted, the output displays the message “Media not present or
accessible.”
FTOS#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 Sensor7
Sensor8 Sensor9
--------------------------------------------------------------------------------
----------------
1 51 51 64 61 61 61 67 61 64
66
FTOS#
media slot (OPTIONAL) Enter the keyword media followed by the stack ID of the stack member
for which you want to display pluggable media inventory.
optional-module (OPTIONAL) Enter the keyword optional-module to display optional module
information.
Version 8.3.17.0 Supported on M I/O Aggregator