Debugging and Diagnostics | 265
Environmental Monitoring
Aggregator components use environmental monitoring hardware to detect transmit power readings,
receive power readings, and temperature updates. To receive periodic power updates, you must enable the
enable optic-info-update interval command. The output in Figure 22-6 shows the environment status.
show hardware stack-unit {0-5} cpu party-bus
statistics
View input and output statistics on the party bus, which carries
inter-process communication traffic between CPUs.
show hardware stack-unit {0-5} drops unit {0-0}
port {33-56}
View the ingress and egress internal packet-drop counters, MAC counters
drop, and FP packet drops for the stack unit on per port basis. It assists in
identifying the stack unit/port pipe/port that may experience internal drops.
show hardware stack-unit {0-5} stack-port
{33-56}
View the input and output statistics for a stack-port interface.
show hardware stack-unit {0-5 unit {0-0} counters
View the counters in the field processors of the stack unit.
show hardware stack-unit {0-5} unit {0-0} details
View the details of the FP devices and Hi gig ports on the stack-unit.
show hardware stack-unit {0-5} unit {0-0}
execute-shell-cmd {command}
Execute a specified bShell commands from the CLI without going into the
bShell.
show hardware stack-unit {0-5} unit {0-0}
ipmc-replication
View the Multicast IPMC replication table from the bShell.
show hardware stack-unit {0-5} unit {0-0}
port-stats [detail]
View the internal statistics for each port-pipe (unit) on per port basis.
show hardware stack-unit {0-5} unit {0-0} register
View the stack-unit internal registers for each port-pipe.
show hardware stack-unit {0-5} unit {0-0}
table-dump {table name}
View the tables from the bShell through the CLI without going into the
bShell.
Table 21-2. show hardware Commands
Command Description