Owner`s manual

Debugging and Diagnostics | 263
Figure 21-3. Taking a Stack Unit Offline
2. Use the show system brief command from EXEC Privilege mode to confirm offline status (Figure 22-4).
Figure 21-4. Verifying the Offline/Online Status of a Stack Unit
Trace Logs
In addition to the syslog buffer, the Dell Networking operating software (FTOS) buffers trace messages
which are continuously written by various FTOS software tasks to report hardware and software events
and status information. Each trace message provides the date, time, and name of the FTOS process. All
messages are stored in a ring buffer and can be saved to a file either manually or automatically upon
failover.
Auto Save on Crash or Rollover
Exception information on Master or Standby units is stored in the flash:/TRACE_LOG_DIR directory.
This directory contains files that save trace information when there has been a task crash or timeout.
On a Master unit, you can reach the TRACE_LOG_DIR
files by file transfer protocol (FTP) or by using
the
show file command from the flash://TRACE_LOG_DIR directory.
FTOS#offline stack-unit 2
Warning - Diagnostic execution will cause stack-unit to reboot after completion of diags.
Proceed with Offline-Diags [confirm yes/no]:y
5w6d12h: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 2 down - stack unit offline
5w6d12h: %STKUNIT0-M:CP %IFMGR-1-DEL_PORT: Removed port: Tengig 2/1-48
FTOS#5w6d12h: %STKUNIT1-S:CP %IFMGR-1-DEL_PORT: Removed port: Tengig 2/1-48
FTOS#show system brief | no-more
Stack MAC : 00:01:e8:00:ab:03
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
------------------------------------------------------------------------------------
0 Member not present
1 Management online I/O-Aggregator I/O-Aggregator 8-3-17-38 56
2 Member not present
3 Member not present
4 Member not present
5 Member not present
FTOS#