Deployment Guide

Oversubscription ratio = 10
Dynamic Cell Limit Per port = 59040/29 = 2036 cells
Figure 39. Buer Tuning Points
Deciding to Tune Buers
Dell Networking recommends exercising caution when conguring any non-default buer settings, as tuning can signicantly aect system
performance. The default values work for most cases.
As a guideline, consider tuning buers if trac is bursty (and coming from several interfaces). In this case:
Reduce the dedicated buer on all queues/interfaces.
Increase the dynamic buer on all interfaces.
Increase the cell pointers on a queue that you are expecting will receive the largest number of packets.
To dene, change, and apply buers, use the following commands.
Dene a buer prole for the FP queues.
CONFIGURATION mode
buffer-profile fp fsqueue
Dene a buer prole for the CSF queues.
CONFIGURATION mode
buffer-profile csf csqueue
Change the dedicated buers on a physical 1G interface.